gototopgototop

MC-S-LogoMC-S - Your Rugged Partner!


Oranje Nassaulaan 20
3708 GD  Zeist
The Netherlands
+31(0)30 69 32459
Skype: MCSNederland
info@mc-s.nl

Home Bay Systems Bay Wind Noise Microphone
Wind Noise Microphone

Bay Systems Wind Noise Microphone

windnoise3

An accurate and cost effective solution for the measurement of wind/turbulent flow induced noise

The Bay Systems Wind Noise Microphone is supplied with all signal conditioning needed to allow the signal to be recorded using a standard ADC system. The data presented in this technical note was collected using the BAY Acquisition and Reporting System (BARS) which is a 24bit ADC with a choice of +/-1v and +/-10volt range and IEPE power. The input range used for this
work was +/-10v. The typical frequency response of the BAY WNM is flat to better than +/- 3dB
from 80Hz-8kHz.